
INPUT
MODE
SWITCH
OPERATE
SWITCH
hi-LO
DEVIATION
FREQUENCY
SWITCH
MODULATION
TEST
a
special
mark
at
the maximum
permitted
deviation of 1350 Hz.
The Acid Test. Is the C -12B
reliable? Is
it
really a
secondary
frequency standard
the
CBer and the
service shop can
depend
on?
To
find
out,
we
checked
the C -12B against
a Hewlett-
Packard
counter
with a
known
accuracy
of 1 Hz. The results are
shown in
the table.
Column 1 shows
the channel, col-
Channel
Frequency
in Hz
C-128
Output
Error
in Hz
1
26965000
26964971 29
2
26975000
26974990
10
3
26985000
26985002 2
4
27005000
27004992 8
5 27015000
27014992
8
6 27025000
27024995 5
7 27035000
27035002 2
8 27055000
27054986
14
9
27(65000
27065014 14
10
27075000
27075004 4
11 27085000
27085018 18
12 27105000
27104979 21
13
27115000
27114984 16
14 27125000
27125000
1
15 27135000
27134951
49
16 27155000
27155002
2
17 27165000
27165009
9
18
27175000
27175002
2
19 27185000
27185004
4
20
27205000
27205016
16
21
27215000
27215003
3
22 27225000
27225019
19
23
27255000
27255037
37
24
No crystal
provided
(spare)
58
OSCILLATOR
TUBE
A.F.
AMP
a -ll
COUNTER
BATTERY
COMPARTMENT
CRYSTAL
BANK a
INDIVIDUAL
FREQUENCY
CALIBRATING
TRIMMERS
Operating
panel of
the International
Crys-
tal C -12B (left)
and
internal layout (above)
shows
th^
major portions of
this ac-
curate
( 100 Hz) frequency
meter for CB.
umn 2 the assigned
frequency, column
3 the
actual
reference frequency
of the C -12B, and
column 4
the
C -12B's
error
in Hz. Note
that the error
is
less than
the specified
100
Hz and
in many instances
less than 10
Hz.
Allowing for
interpolation
of
the
meter
scale
(which is calibrated
in units of
60 Hz),
the
maximum error
of
the model
we
obtained
would be
considerably
less
than
100 Hz. Fre-
quency drift
from the moment of throwing
the power
switch
to
the moment
of measure-
ment (a
few
seconds)
was less
than
10 Hz,
again
keeping total
error
well
within
the
claimed 100 Hz.
As far as
the
mechanical operation is con-
cerned, things couldn't
be easier.
You feed
in the transmitter's
signal, set
the mode
switch to
RF,
adjust
the level control
until
the
meter
pointer
lines up
with
a
scale mark,
then switch to
deviation. The
meter then in-
dicates frequency deviation
instantly;
total
measurement
time is less
than 10 seconds.
Other
Functions. To use the C -12B as
a
power meter, you simply
set the mode switch
to
RF
and
turn the
level
control
full clock-
wise. The
C -12B
then indicates the transmit-
ter's output power, and
in the
unit
we
tested
it does
so
with
an accuracy
better than the
claimed
Vs
watt.
For example,
when
the
actual power
fed into the unit
was
3.0
watts,
the C -12B
indicated an input
of
3.2
watts.
Since
the C -12B's
meter
is
damped, a sus-
tained
word rather than a string
of words
must
be used
for
modulation
tests in
order
to
permit the
meter
to
rise to
peak value. For
example,
when the speech
input was a long
(Continued on
page 118)
Rnaro-TV
EXPERIMENTER
Comentarios a estos manuales